首页 | 本学科首页   官方微博 | 高级检索  
     


Effect of needle orientation during arteriovenous access puncture on needed compression time after hemodialysis: A randomized controlled trial
Authors:Valérie Loizeau  Hanan Tanouti  Audrie Marcheguet  Guillaume Loubière  Philippe Aegerter  Hocine Drioueche  Sandra Pembebjoglou
Affiliation:1. Centre Hospitalier Intercommunal De Poissy Saint Germain, Poissy, France;2. Dpt Santé Publique U1018 UVSQ INSERM GIRCI IdF-UFR Médecine Paris-Ile-de-France-Ouest Université Versailles St-Quentin, Boulogne, France;3. Centre Hospitalier, Mantes La Jolie, France
Abstract:

Background

There are two techniques for puncturing an arteriovenous fistula: one where the needle is inserted bevel up and then rotated to a bevel down position, and another where the needle is inserted bevel down. The aim of this study was to compare these two methods of needle insertion on minimum compression time required for hemostasis after needle removal.

Methods

This was a prospective, randomized, cross-over, blinded, single-center, routine care study. Each patient's average post-dialysis puncture site compression time was determined during a 2-week baseline period while using bevel-up access puncture. Subsequently, minimum post-dialysis puncture-site compression time was determined during each of two sequential follow-up periods, during which fistula puncture was done with needles inserted bevel up or down, respectively. The order of treatments (bevel up or bevel down insertion) was randomized. During each follow-up period, the minimum compression time necessary to avoid bleeding on needle removal was determined by progressively shortening the compression time. Puncture-associated pain was also assessed as prepump and venous pressures and ability to achieve desired blood flow rate during the dialysis session.

Results

Forty-two patients were recruited. The baseline compression time after needle removal averaged 9.99 ± 2.7 min During the intervention periods, the minimum compression time was on average 10.8 min (9.23–12.4) when the access needles had been inserted bevel down versus 11.1 min (9.61–12.5) when the access needles had been inserted bevel up (p = 0.72). There was no difference in puncture-associated pain between the two insertion techniques, and no difference in prepump or venous pressures or ability to achieve the desired blood flow rate during the dialysis session.

Conclusion

Bevel-up and bevel-down needle orientation during arteriovenous fistula puncture are equivalent techniques in terms of achieving hemostasis on needle removal, and puncture-associated pain.
Keywords:arteriovenous fistula  chronic disease  fistula puncture  hemodialysis  nursing care
设为首页 | 免责声明 | 关于勤云 | 加入收藏