摘    要:通过对各种电机接线盒引线结构的分析对比,提出了一种新颖的电机引线结构:用一个接线螺栓压接两根引接线并且接线螺栓采用分开加工,解决了隔爆型低压大容量电机定子电流大及接线螺栓加工难的难题,为隔爆型低压大容量电机的开发奠定了基础。

关 键 词:低压大容量电机  隔爆  引线  压接
文章编号:1004-9118(2007)02-0030-03
修稿时间:2007-03-07

Design on the Connection and Wiring in the Terminal Box Used for Large-size Flameproof Low-voltage Motor
LI Meng-lin,ZHAO Yan,GENG Zhi-qi. Design on the Connection and Wiring in the Terminal Box Used for Large-size Flameproof Low-voltage Motor[J]. Electric Explosion Protection, 2007, 0(2): 30-32
Authors:LI Meng-lin  ZHAO Yan  GENG Zhi-qi
Affiliation:Nanyang Explosion Protection Group Co., Ltd, Henan Nanyang 473008
Abstract:By comparison of the structures of different terminal boxes,a newly structure for leading wiring for motor put forward: two leading fixture wires are clamping connected by one bolt.With this connection method,it is solved the problems of large current in stator for flameprooof low-voltage large-sized motor and hardly to machine the wiring bolts.