首页 | 本学科首页   官方微博 | 高级检索  
     


A CFD study of wet gas metering over-reading model under high pressure
Abstract:The venturi flow meter is increasingly being preferred in multiphase flow measurement because of its shorter upstream and downstream straight sections, less influenced by the flow pattern and relatively small pressure loss. However, when the venturi is used for wet gas measurement, the over-reading phenomenon occurs due to the presence of a small amount of liquid. Many scholars have established over-reading models to correct the measured values of wet gas. Regrettably, the applicability of these over-reading models under actual high pressure operating conditions has not been verified. Therefore, this review focuses on numerical simulation of the flow of wet gas in the venturi tube under high pressure conditions (11MPa/13MPa/15 MPa). The discrete phase model (DPM) and the standard k-ε model was employed in this review. The simulations results reveals the flow characteristics of wet gas in venturi tube, which includes the flow field distributions, droplet concentration distributions and wall pressure profile distributions, and indicates that the over-reading values increases with the increase of Lockhart-Martinelli parameters and gas volume flow rate, but decreases with the increase of pressure. Moreover, the ISO model has the best performance under high pressure conditions.
Keywords:CFD  Wet gas  Venturi flow meter  Flow characteristics  Over-reading  High pressure
本文献已被 ScienceDirect 等数据库收录!