摘    要:讨论了室内空气计算参数变化对不同建筑的空调系统经济性的影响。分析结果表明,在大多数情况下,降低室内相对湿度,空调系统的能耗均可下降;无论在哪种情况下,降低室内相对湿度,空调系统的一次投资都明显减少,而且降低幅度明显大于能耗的变化。同时,室内相对湿度的降低可以明显提高人体舒适感和室内空气品质。

关 键 词:室内空气 空调系统 经济分析
修稿时间:2000-02-14

Effects of indoor air design conditions on first investment and operating costs of air conditioning systems
By Yin Ping. Effects of indoor air design conditions on first investment and operating costs of air conditioning systems[J]. Journal Heating Ventilating and Airconditioning, 2002, 32(2): 21-25
Authors:By Yin Ping
Abstract:Discusses the economic results from the selected design conditions for various spaces of buildings. The analysis leads to the finding that with lowerd relative humidity the energy consumption will decrease in most cases while the first investment of an air conditioning system will reduce even greater without exception. Reiterates that lowerd relative humidity helps notably improve human body comfort and indoor air quality.
Keywords:indoor air design conditions   air conditioning system   economic analysis