首页 | 本学科首页   官方微博 | 高级检索  
     

增强纤维约束混凝土轴压应力-应变关系试验研究
引用本文:金熙男,潘景龙,刘广义,来文汇. 增强纤维约束混凝土轴压应力-应变关系试验研究[J]. 建筑结构学报, 2003, 24(4): 47-53
作者姓名:金熙男  潘景龙  刘广义  来文汇
作者单位:哈尔滨工业大学土木工程学院,哈尔滨工业大学土木工程学院,哈尔滨工业大学土木工程学院,哈尔滨工业大学土木工程学院 黑龙江哈尔滨150090,黑龙江哈尔滨150090,黑龙江哈尔滨150090,黑龙江哈尔滨150090
摘    要:本文通过不同增强纤维包裹的混凝土圆截面短柱的轴压试验,并结合国内外同类试验结果分析,认为纤维约束混凝土根据约束刚度比βj或约束比ξ的不同,可分为强、弱约束两种不同情况,分别讨论了它们在弹性、弹塑性及强化或退化不同阶段核心混凝土所处的状态和应力-应变曲线的特点,认为约束刚度比决定了强化或退化段的直线斜率,约束比决定了强约束混凝土的强度。文章给出了适用于纤维强、弱约束混凝土统一函数形式的应力-应变曲线方程及特征点和相应系数的确定方法,其结果与试验值吻合较好。

关 键 词:应力-应变关系  约束比  约束刚度比  约束混凝土  增强纤维  
文章编号:1000-6869(2003)04-0047-07
收稿时间:2003-08-05
修稿时间:2002-06-01

Research of stress-strain curve of concrete confined by fiber reinforced plastics under axial compression
JIN Xinan,PAN Jinglong,LIU Guangyi,LAI Wenhui. Research of stress-strain curve of concrete confined by fiber reinforced plastics under axial compression[J]. Journal of Building Structures, 2003, 24(4): 47-53
Authors:JIN Xinan  PAN Jinglong  LIU Guangyi  LAI Wenhui
Affiliation:JIN Xinan,PAN Jinglong,LIU Guangyi,LAI Wenhui (School of Civil Engineering,Harbin Institute of Technology,Harbin,China)
Abstract:Based on the experimental studies on short concrete round section columns wrapped with different types of fiber reinforced plastics (FRP) and the analysis of the same by experiments, the confined concrete wrapped with fiber can be divided into two kinds, i.e. the strong confined concrete and weak confined concrete according to the confinement stiffness ratio βj or confinement ratio ξ. The paper discussed the characteristics of the stress strain curve and the state of the core concrete in three stages,namely the elastic, elastic plastic and strengthening or degenerating stages. The paper points out that the confinement stiffness ratio βj determines the slope of strengthening stage (degenerating stage),and confinement ratio ξdecides the ultimate strength of confinement concrete. The stress strain curve equation, latent point and the method of ascertaining corresponding quotiety applicable to the unitive function form of strong confined concrete and weak confined concrete are given, and the results appear to be in good agreement with the testing results.
Keywords:fiber reinforced plastics  confinement concrete  confinement stiffness ratio  confinement ratio  stress strain relationship
本文献已被 CNKI 万方数据 等数据库收录!
点击此处可从《建筑结构学报》浏览原始摘要信息
点击此处可从《建筑结构学报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏