首页 | 本学科首页   官方微博 | 高级检索  
     

整体现浇组合过梁配筋形式与力学性能研究
引用本文:邢国起,肖洪天,伊廷成,杨振刚.整体现浇组合过梁配筋形式与力学性能研究[J].四川建筑科学研究,2014(1):23-26,52.
作者姓名:邢国起  肖洪天  伊廷成  杨振刚
作者单位:[1]山东科技大学土木建筑学院,山东青岛266590 [2]潍坊学院建筑工程学院山东潍坊261061 ,山东青岛266590 [3] 山东莱钢建设有限公司,山东青岛266071
基金项目:潍坊市科技发展计划项目(201104049)
摘    要:研究了非抗震作用下整体现浇组合过梁的配筋形式,通过本文建立的模型进行了整体现浇组合过梁配筋量的计算,利用试验验证了上述配筋形式的可行性,得到如下结论:1)过梁部分受拉区钢筋锚入连梁或框梁的锚固长度36 d(非抗震设计)满足要求,过梁部分受拉区配筋形式理论上可行;2)按照连梁或框梁部分与过梁部分分别计算的配筋量,当达到正常使用极限状态时,连梁或框梁部分受压区钢筋与过梁部分受拉区钢筋能够达到甚至超过屈服强度,而连梁或框梁部分受拉区钢筋则未达到屈服强度,将连梁部分受拉区钢筋面积减少20%左右时才能达到屈服强度;3)过梁部分受拉区钢筋面积需要增加40%左右才能保证设计的安全可靠度.

关 键 词:整体现浇组合过梁  配筋形式  Ansys有限元分析  应变试验

Research of the form of reinforcing bar and mechanical properties about integral cast-in-situ composite lintel
XING Guoqi,',XIAO HongtianI,YI Tingcheng,YANG Zhengang.Research of the form of reinforcing bar and mechanical properties about integral cast-in-situ composite lintel[J].Building Science Research of Sichuan,2014(1):23-26,52.
Authors:XING Guoqi    XIAO HongtianI  YI Tingcheng  YANG Zhengang
Affiliation:3 ( 1. School of Civil Engineering and Architecture, Shandong University of Science and Technology, Qingdao 266590, China ; 2. School of Architecture and Engineering, Weifang University, Weifang 261061, China; 3. Shandong Lai Gang Construction Co. , Ltd. , Oingdao 266071. China)
Abstract:The form of reinforcing bar of integral cast-in-situ composite lintel under non seismic action was studied and the area of reinforcing bar in integral cast-in-situ composite lintel was calculated according to the model established in this paper. The feasibility of the form of reinforcing bar was verificated by the experiment and the conclusion was get that: 1 ) The anchorage length ( 36 d) that reinforcing bar of tensile zone in lintel anchored in frame beams or coupling beams met the requirements and the form of reinforcing bar in lintel was feasible in theory. 2) When reaching to serviceability limit state, the reinforcing bar of compression zone in frame beams or coupling beams and the reinforcing bar of tensile zone in lintel can reach to the yield strength and the reinforcing bar of tensile zone in frame beams or coupling beams can not reach to the yield strength. When the area of reinforcing bar in tensile zone of frame beams or coupling beams was reduced of about 20%, the reinforcing bar can reach to the yield strength. 3 ) In order to ensure the reliability of safety,the area of reinforcing bar in tensile zone of lintel should be increased by about 40%.
Keywords:integral cast-in-situ composite lintel  the form of reinforcing bar  analysis of finite element  strain test
本文献已被 CNKI 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号