摘    要:依托实际工程,利用ETABS和PKPM等结构计算软件,建立分析模型,研究高地震烈度地区火力发电厂钢筋混凝土结构主厂房设置效能阻尼器后抗震性能,进一步对经济造价进行对比。结果表明,设置阻尼器后,主厂房结构性能得到提高,造价降低,节省了投资。

关 键 词:高地震烈度  消能阻尼器  主厂房  抗震性能

THE STRUCTURE BEHAVIOR OF THERMAL POWER PLANT'S MAIN BUILDING WITH ENERGY DISSIPATION DAMPER ON HIGH EARTHEQUAKE INTENSITY AREA
Abstract:Based on real project,an analytic model is set up with the ETBAS & PKPM to research into the seismic behavior of the thermal power plant's main building with energy dissipation damper on high earthquake intensity area.And the cost of the main building is discussed.The results show that its structure behavior is enhanced and the cost is decreased after the dissipation dampers are used in the main building.
Keywords:high earthquake intensity energy dissipation damper main mill building anti-seismic structure behavior