首页 | 本学科首页   官方微博 | 高级检索  
     


Development,preclinical evaluation and validation of a novel quick vascular closure device for transluminal,cardiac and radiological arterial catheterization
Authors:C Linti  M Doser  H Planck  S Oberhoffner  E Mueller  M Renardy  J Biesinger  B Neumann  K Stang  T O Greiner  C Schlensak  S Krajewski  H P Wendel
Affiliation:1.German Institutes of Textile and Fiber Research (DITF),Denkendorf,Germany;2.ITV Denkendorf Produktservice GmbH,Denkendorf,Germany;3.Department of Thoracic, Cardiac and Vascular Surgery,Clinical Research Laboratory, University Hospital Tuebingen,Tuebingen,Germany;4.Department of General, Visceral and Transplant Surgery,University Hospital of Tuebingen,Tuebingen,Germany
Abstract:Following percutaneous coronary intervention, vascular closure devices (VCDs) are increasingly used to reduce time to ambulation, enhance patient comfort, and reduce potential complications compared with traditional manual compression. Newer techniques include complicated, more or less automated suture devices, local application of pads or the use of metal clips and staples. These techniques often have the disadvantage of being time consuming, expensive or not efficient enough. The VCD failure rate in association with vascular complications of 2.0–9.5%, depending on the type of VCD, is still not acceptable. Therefore, the aim of this study is to develop a self-expanding quick vascular closure device (QVCD) made from a bioabsorbable elastic polymer that can be easily applied through the placed introducer sheath. Bioabsorbable block-co-polymers were synthesized and the chemical and mechanical degradation were determined by in vitro tests. The best fitting polymer was selected for further investigation and for microinjection moulding. After comprehensive haemocompatibility analyses in vitro, QVCDs were implanted in arterial vessels following arteriotomy for different time points in sheep to investigate the healing process. The in vivo tests proved that the new QVCD can be safely placed in the arteriotomy hole through the existing sheath instantly sealing the vessel. The degradation time of 14 days found in vitro was sufficient for vessel healing. After 4 weeks, the remaining QVCD material was covered by neointima. Overall, our experiments showed the safety and feasibility of applying this novel QVCD through an existing arterial sheath and hence encourage future work with larger calibers.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号