首页 | 本学科首页   官方微博 | 高级检索  
     


Evaluation of a Failed Water Wall Boiler Tube
Authors:Neal Hanke
Affiliation:(1) Materials Evaluation and Engineering, Inc., 13805 1st Avenue North Suite 400, Plymouth, MN 55441, USA
Abstract:A metallurgical evaluation was performed to investigate a crack in a lateral water wall boiler tube. The 2.5-in. diameter, carbon-steel tube was removed from a 125 MW coal-fired boiler used for base load electric power generation. Visual examination, microstructure characterization, and SEM/EDS analysis were used to determine that hydrogen damage was the primary failure mechanism.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号