尿素装置调节阀NS-HV-102阀杆断裂原因分析及改进应用
引用本文:苏爱丽,王疆,沈晓磊,沈新群. 尿素装置调节阀NS-HV-102阀杆断裂原因分析及改进应用[J]. 仪器仪表用户, 2014, 0(4): 46-48
作者姓名:苏爱丽  王疆  沈晓磊  沈新群
作者单位:中国石油乌鲁木齐石化公司化肥厂;
摘    要:乌石化一尿素装置NS-HV-102调节阀阀杆连续断裂3次,其根本原因是该阀阀内部件设计结构不合理、导向结构不合理,造成配合间隙过大,直接造成振动致使阀杆断裂。

关 键 词:阀杆断裂原因分析  改进阀芯及阀杆连接结构  延长调节阀运行周期

Analysis and Improvement of NS-HV-102 Causes Valve Stem Fracture Regulation of Urea Plant
Su Aili,Wang Jiang,Shen Xiaolei,Shen Xinqun. Analysis and Improvement of NS-HV-102 Causes Valve Stem Fracture Regulation of Urea Plant[J]. Electronic Instrumentation Customer, 2014, 0(4): 46-48
Authors:Su Aili  Wang Jiang  Shen Xiaolei  Shen Xinqun
Affiliation:(China petroleum Urumqi Petrochemical Co instrument workshop in Xinjiang chemical fertilizer plant, Urumqi,830019,China)
Abstract:a urea plant of Urumqi Petrochemical NS-HV-102 valve stem continuous three faults,the fundamental reason is the valve intemal parts design unreasonable structure,guide structure unreasonable,cause the clearance is too large,directly caused by vibration causing stem fracture.
Keywords:analysis of stem breakage causes the spool and valve stem connection structure improvement to extend valve operation cycle