摘    要:光-电检测法应用于气-固两相流微粒浓度的测量时,被测固体颗粒直径的变化对测量结果将产生明显影响.以致使测量结果与实际状态相反.本文分析了固体颗粒粒径对测量的影响,并提出了有效的修正方法.

关 键 词:气-固两相流,固体微粒浓度,微粒粒径,光-电检测法

THE INFLUENCE OF PARTICAL DIAMETER ON THE OPTICAL-ELECTRIC TESTING OF SOLID PARTICAL CONCENTRATION IN A GAS-SOLID TWO PHASE FLUID
Chen Yuandi.THE INFLUENCE OF PARTICAL DIAMETER ON THE OPTICAL-ELECTRIC TESTING OF SOLID PARTICAL CONCENTRATION IN A GAS-SOLID TWO PHASE FLUID[J].Industrial Engineering Journal,1994(4).
Authors:Chen Yuandi
Affiliation:Chen Yuandi
Abstract:When the optical-electric testing is used to measure panical concentration in a gassolid two--phase fluid. The measurement result is obviously affected by the change of panical diameter. In worse cases,even contrary to reality. This paper analyses the infulence of panical diameter on the measurement and puts forward an amending method.