摘    要:合理的无功就地补偿和选择变压器容量可以降低损耗,提高系统运行的经济性,是电力需求侧管理的重要内容。文章将两者有效结合,推导出最经济运行的公式,通过简单迭代来确定无功就地补偿容量和变压器容量的选择。算例证明了其效果。

关 键 词:无功补偿  变压器容量  最佳负载率

Selection of Reactive Compensation and Transformer Capacity
WANG Zheng-feng,ZHAO Da-qin,BAI Jian,XU Chang-lin.Selection of Reactive Compensation and Transformer Capacity[J].Power Capacitor $ Reactive Power Compensation,2007,28(3).
Authors:WANG Zheng-feng  ZHAO Da-qin  BAI Jian  XU Chang-lin
Abstract:Rational planning of local reactive compensation and transformer capacity is very important for demand side management to reduce power losses and improve the economical power system operation.The best economical formulas are deduced based on the combination of both.The capacity determination of local reactive compensation and the rational transformer capacity can be got through simple iteration.Examples are presented to show the effectiveness.