Affiliation:1. Friedrich-Alexander-Universität Erlangen-Nürnberg (FAU), Zahnklinik 1 – Zahnerhaltung und Parodontologie, Forchungslabor für dentale Biomaterialien, Glueckstrasse 11, 91054 Erlangen, Germany;2. Department of Restorative Dentistry, Faculty of Dentistry, University of Concepción, Concepción, Chile;3. Institut für Struktur- und Funktionskeramik, Montanuniversität Leoben, A-8700 Leoben, Austria
Abstract:The testing of fracture toughness becomes problematic when only limited amount of material is available that hinders the production of typical beam specimens to be tested in bending. Here we explore fracture toughness testing methodologies that allow for small discs and plates having surface cracks to be tested in biaxial flexure using the Ball-on-3-balls (B3B) set-up, or sawed notches as in the Compact Tension geometry. The B3B-KIc test has shown to be versatile and account for a very small overestimation of the KIc-value in the order of 0.8–1.25% due to in-plane crack mispositioning, and a maximum of 4% if a worst-case scenario of additional out-of-plane mispositioning is assumed. The geometrical factor in the standard SCF method, derived by Newman and Raju, resulted in an overestimation of ~8% of the KIc-value compared to the new calculation by Strobl et al. for materials with Poisson’s ratio <0.3.
Keywords:Dental  Ceramics  Composites  Fracture toughness  Testing