摘    要:介绍了南钢带钢厂高压水除鳞系统,分析了由于老系统改造及PLC升级而引起的电气干扰。并提出了相应的抗干扰措施。

关 键 词:高压水除鳞  变频器  自动控制
文章编号:1006-6764(2007)06-0066-03
收稿时间:2007-07-19
修稿时间:2007-07-19

Analysis of Electrical Interference in High Pressure Water Scale Removing in Strip Steel Plant
YANG Fang,ZHOU Feng-yin. Analysis of Electrical Interference in High Pressure Water Scale Removing in Strip Steel Plant[J]. Metallurgical Power, 2007, 0(6): 66-68
Authors:YANG Fang  ZHOU Feng-yin
Affiliation:YANG Fang, ZHOU Feng-yin (Strip Steel Plant, Nanjing Integrated Iron & Steel Co., Nanjing, Jiangsu 210035, China)
Abstract:The high pressure water scale removing system of Nanjing Integrated Iron & Steel Co. was introduced. Electrical interference due to reconstruction of the old system and PLC upgrading was analyzed and the related anti-interference measures were raised.