首页 | 本学科首页   官方微博 | 高级检索  
     

超超临界660MW锅炉排烟温度偏高的原因分析
引用本文:孙浩,唐健. 超超临界660MW锅炉排烟温度偏高的原因分析[J]. 锅炉制造, 2010, 0(4): 13-15
作者姓名:孙浩  唐健
作者单位:哈尔滨锅炉厂有限责任公司,黑龙江,哈尔滨,150046;哈尔滨锅炉厂有限责任公司,黑龙江,哈尔滨,150046
摘    要:针对660MW超超临界直流锅炉,通过运行数据与设计数据的对比,对锅炉投运以来一直存在排烟温度高的问题,进行了原因分析,并提出了诊断调整试验建议。

关 键 词:660MW超超临界  排烟温度  调整试验

Analyse of Flue Gas Temperature Higher Then Design Value for the 660MW Ultra Supercritical Boiler
Sun Hao,Tang Jian. Analyse of Flue Gas Temperature Higher Then Design Value for the 660MW Ultra Supercritical Boiler[J]. Boiler Manufacturing, 2010, 0(4): 13-15
Authors:Sun Hao  Tang Jian
Affiliation:(Harbin Boiler Co. Ltd Harbin 150046,China)
Abstract:This paper introduces the reason of the 660MW ultra supercritical boiler, that the flue gas temperature is higher then design value since the boiler put in service. It is analysed according to the comparision between operating data and design value, and some adjustment tests are advised.
Keywords:660MW ultra super critical boiler  flue gas temperature  adjustment test