十里泉电厂125MW机组异常振动的诊断及处理 |
| |
引用本文: | 刘玉智,许怀志,何卫国. 十里泉电厂125MW机组异常振动的诊断及处理[J]. 山东电力技术, 2005, 0(5) |
| |
作者姓名: | 刘玉智 许怀志 何卫国 |
| |
作者单位: | 山东电力研究院,山东,济南,250002;华电滕州新源热电有限公司,山东,枣庄,277500 |
| |
摘 要: | 十里泉电厂2号机组大修后启动升速至3000r/min时,3号、5号轴承垂直振动分别为64μm、75μm,3X轴振为154μm,在处理过程中4X轴振变为182μm,低压转子和发电机转子的轴承振动相互影响,通过在发电机转子高速动平衡使振动水平达优良,本文详细介绍了该异常振动现象特征、原因及处理过程。
|
关 键 词: | 125MW机组 振动 诊断 动平衡 |
Abnormal Vibration Diagnosis and Treatment of Unit 125MW in Shiliquan Power Plant |
| |
Abstract: | While the speed is 3000r/min during start-up after over-haul of unit 2 in Shiliquan Power Plant,the bearings vibration of No.3 and No.5 are 64μm and 75μm,3X shaft vibration is 154μm,During fault diagnosis,4X shaft vibration increases to 182μm,the bearings vibration of LP and generator rotor influences each other.the vibration was excellent after generator rotor high-speed balance.The article detailed the abnormal vibration phenomena characteristic,reasons and treat process. |
| |
Keywords: | 125MW unit vibration diagnosis balance |