摘    要:根据300MW CFB锅炉床压分布的特点,分析了CFB锅炉的翻床现象及原因,提出了可采取的预防措施及翻床后的处理方法,认为对双支腿结构CFB锅炉避免炉膛两侧床料失衡造成翻床是有效的。

关 键 词:CFB锅炉  两床失稳  翻床
文章编号:1004-3950(2007)05-0068-05
修稿时间:2007-08-02

The processing methods of turning-over for two beds in 300MW circulating fluidized bed boiler
WANG Jia-wan. The processing methods of turning-over for two beds in 300MW circulating fluidized bed boiler[J]. Energy Engineering, 2007, 0(5): 68-72
Authors:WANG Jia-wan
Affiliation:Yunnan Datang International Honghe Power Generation Co.,Ltd,Kaiyuan 661600,China
Abstract:According to the characteristics of bed pressure distribution in 300MW circulating fluidized bed boiler,the phenomenon and causes of turning-over of beds,prevention measures,as well as treatment methods after turning-over of beds were proposed,which were effective for CFB boiler to avoid turning-over of beds caused by material imbalance were analyzed.