COMPARISON OF REPEATED REHEAT TESTS OF VARIOUS GRADES OF FIREBRICK WITH SERVICE RESULTS |
| |
Authors: | W T Tredennick J F Kelly R C Burt |
| |
Affiliation: | United;States Navy Yard Naval Boilerand Turbine Laboratory Philadelphia 12, Pennsylvania |
| |
Abstract: | Representative brands of Navy-approved class A brick (60% alumina), class B brick (superduty), and special firebrick (in a price group above the 60% alumina brick) were installed in a naval boiler operating continuously at the Naval Boiler and Turbine Laboratory. The permanent volume change of the various brands, subjected to repeated reheat tests at 2912°F., is compared with their service life. |
| |