首页 | 本学科首页   官方微博 | 高级检索  
     

1 000 MW超超临界机组瓦振动分析及处理
引用本文:陈建县. 1 000 MW超超临界机组瓦振动分析及处理[J]. 电力建设, 2009, 30(12): 49-51
作者姓名:陈建县
作者单位:(浙江北仑电厂,浙江省宁波市,315800)
摘    要:浙江北仑第三发电有限公司1 000 MW超超临界机组7号机4号瓦在运行过程中出现瓦振超标的故障,经检查发现引起振动的根本原因是轴瓦支承垫块的球面与轴承支架圆柱面接触不良。介绍了瓦振故障及其特征,针对故障原因及现场实际,提出了改进措施,有效解决了瓦振问题。

关 键 词:1 000 MW超超临界机组  振动  动平衡  接触面  
收稿时间:2010-01-25
修稿时间:2010-01-25

1000 MW USC Unit Bearing Bush Vibration Analysis and Remedy
CHEN Jian-xian. 1000 MW USC Unit Bearing Bush Vibration Analysis and Remedy[J]. Electric Power Construction, 2009, 30(12): 49-51
Authors:CHEN Jian-xian
Affiliation:CHEN Jian-xian(Zhejiang Beilun Power Plant,Ningbo 315800,China)
Abstract:The vibration fault of No.4 bearing appeared in the operation of unit No.7 in ZheJiang Beilun No.3 Power Plant,and the basic reasons are subject to poor contact between the bearing supporting plate spherical surface and bearing support cylindrical shell.The phenomena and characters of this fault are introduced.According to the fault reason and the field condition,the improved measures are put forward to solve the bearing vibration problem.
Keywords:1000 MW USC unit  vibration  dynamic balance  contact surface  
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《电力建设》浏览原始摘要信息
点击此处可从《电力建设》下载全文