摘    要:本文分析了造成室内空气品质恶化的原因,介绍了当前国外及香港地区采用的室内空气品质标准及相关的处理方法.同时介绍了为满足室内空气品质要求,组合式空调机组应具备的特点.实现室内空气品质改善和空调节能的有机结合.

关 键 词:室内空气品质  标准  组合式空调机组

IAQ AND AIR HANDLING UNITS
SUN Yijian.IAQ AND AIR HANDLING UNITS[J].Refrigeration and Air-conditioning,2001,1(6):17-20.
Authors:SUN Yijian
Affiliation:Hunan University
Abstract:In order that IAQ can be improved and the air-conditioning energy consump- tion can be saved at the same time, the reasons of the degradation of IAQ are analyzed, and the IAQ standards adopted in Hong Kong nowadays as well as its dealing--methods are also men- tioned in this paper. Furthermore, the characters of air handling units are introduced in order to meet the IAQ demands.
Keywords:IAQ  standard  air handling units