首页 | 本学科首页   官方微博 | 高级检索  
     


Monolithic Uncooled 8 × 8 Bolometer Arrays Based on Poly-SiGe Thermistor
Authors:Ruifeng Yue  Liang Dong  Litian Liu
Affiliation:1. Department of Electrical and Computer Engineering, University of Wisconsin-Madison, 1415 Engineering Drive, Madison, WI, 53706, USA
Abstract:This paper presents a monolithic uncooled 8 × 8 bolometer array with polycrystalline silicon-germanium (poly-SiGe) thermistors as active elements. The poly-SiGe films are deposited by ultrahigh vacuum vapor deposition (UHV/CVD) system and the dependence of the temperature coefficient of resistance (TCR) on annealing temperature has been investigated. To decrease the thermal conductance of the bolometer, the poly-SiGe thermistor was formed on a four leg suspended microbridge. The improved porous silicon micromachining techniques described here enable the integration of the bolometer array with the MOS readout circuitry. The measurements and calculations show that the mean responsivity is 1.07 × 104 V/W with an uncorrected uniformity of 10.5% and a thermal response time of 10.5 ms, and the detectivity of 3.75 × 108 cm Hz1/2/W is achieved at a chopping frequency of 30 Hz and a bias voltage of 5 V.
Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号