首页 | 本学科首页   官方微博 | 高级检索  
     

汽提塔进液管衬里盖板泄漏原因分析及对策
引用本文:徐卫忠.汽提塔进液管衬里盖板泄漏原因分析及对策[J].大氮肥,2011,34(6):415-417.
作者姓名:徐卫忠
作者单位:重庆建峰化丁股份有限公司化肥分公司,重庆,408601
摘    要:介绍汽提塔衬里盖板泄漏情况,并对泄漏部位判断、安全性评估、泄漏部位特点进行分析。通过采取工艺维护和改进在线冲洗方式等措施,未出现泄漏扩大,实现汽提塔泄漏状态下安全运行。

关 键 词:汽提塔  衬里  泄漏  对策

ANALYSIS OF CAUSES FOR LEAKAGE ON LINING COVER OF LIQUID-INTRODUCED TUBE IN STRIPPER AND COUNTER-MEASURES
Xu Weizhong.ANALYSIS OF CAUSES FOR LEAKAGE ON LINING COVER OF LIQUID-INTRODUCED TUBE IN STRIPPER AND COUNTER-MEASURES[J].Large Scale Nitrogenous Fertilizer Industry,2011,34(6):415-417.
Authors:Xu Weizhong
Affiliation:Xu Weizhong(Chongqing Jianfeng Chemical Co.,Ltd.,Fertilizer Branch,Chongqing 408601)
Abstract:The leakage on lining cover in stripper is introduced and the judgment of leaked location, assessment on safety and features on the leaked location are analyzed. By taking both the process maintenance and improvement of on-line flushing the leakage is not spread and a stripper safe operation at the leakage state is realized.
Keywords:stripper  lining  leakage  counter-measures