乙烯装置开车时冷箱高温原因分析及处理
引用本文:徐鹏,王瑶,谢春丽.乙烯装置开车时冷箱高温原因分析及处理[J].当代化工,2011,40(10):1013-1017.
作者姓名:徐鹏  王瑶  谢春丽
作者单位:中国石油抚顺石化公司,辽宁抚顺,113004
摘    要:抚顺乙烯装置检修后开车过程中针对冷箱高温的情况,对丙烯制冷系统、乙烯制冷系统开车时各参数进行分析,结合丙烯制冷系统和乙烯制冷系统及甲烷-氢系统的复迭制冷关系,判断开车过程中冷箱温度过高的原因,通过采取相应措施使装置尽快恢复开车并开车成功.

关 键 词:制冷系统  冷箱  复迭制冷  乙烯装置开车

Cause Analysis and Solutions of the Cold Box High Temperature During the Start-up of Ethylene Plant
XU Peng,WANG Yao,XIE Chun-li.Cause Analysis and Solutions of the Cold Box High Temperature During the Start-up of Ethylene Plant[J].Contemporary Chemical Industry,2011,40(10):1013-1017.
Authors:XU Peng  WANG Yao  XIE Chun-li
Affiliation:XU Peng,WANG Yao,XIE Chun-li(Fushun Petrochemical Company,Liaoning Fushun 113004,China)
Abstract:Aiming at the cold box high temperature situation during the start-up of Fushun ethylene plant after overhaul,running parameters of the propylene refrigeration system and the ethylene refrigeration system during the start-up were analyzed.Combined with the cascade refrigeration relationship of propylene refrigeration system,ethylene refrigeration system and the methane-hydrogen system,reasons to result in cold box high temperature during the start-up were found,and corresponding measures were put forward.
Keywords:Refrigeration system  Cold box  Cascade refrigeration  Start-up of ethylene plant  