摘    要:同样的防跳回路接线,用在同类型的保护设备,如果断路器的分闸时间不同,会有回路接线正确和不正确的结果,所以在验收防跳回路时,要规范验收程序,细心观察,理解回路接线的时间配合,才不会走过场,造成事故隐患.

关 键 词:防止跳跃  时间配合  断路器

Time Cooperation between Anti-jumping Circuit and Circuit Breaker
Liu Weifeng,Liang Hancheng. Time Cooperation between Anti-jumping Circuit and Circuit Breaker[J]. Guangdong Power Transmission Technology, 2007, 0(3): 69-70
Authors:Liu Weifeng  Liang Hancheng
Affiliation:Guangdong Power Technology Improvement Co. Liu Weifeng Liang Hancheng
Abstract:The anti-jumping function of circuit breaker plays an important role in power system. It works properly with the cooperation of protective device and circuit breaker. Otherwise the "jumping" process of breaker would be produced. The importance point is onsite testing about the anti-jumping circuit are presented.
Keywords:Anti-jumping Time cooperation Circuit breaker