首页 | 本学科首页   官方微博 | 高级检索  
     

糖苷对碱性溶液中钢筋表面钝化膜性能的影响
引用本文:周欣,陈韧,杨怀玉,王福会.糖苷对碱性溶液中钢筋表面钝化膜性能的影响[J].中国腐蚀与防护学报,2014,34(2):125-130.
作者姓名:周欣  陈韧  杨怀玉  王福会
作者单位:1. 辽宁科技学院冶金工程学院 本溪 117022;
2. 中国科学院金属研究所 金属腐蚀与防护国家重点实验室 沈阳 110016
基金项目:辽宁省教育厅科学技术一般研究项目 (L2011226) 资助
摘    要:利用动电位极化和表面形貌观察技术,结合电容-电位曲线测量和Mott-Schottky分析,探讨了糖苷化合物对钢筋在含3.5%NaCl的Ca(OH)2饱和溶液中的缓蚀行为和表面钝化膜性能的影响。结果表明,糖苷阻锈剂的加入可有效减缓钢筋的腐蚀,促进钢筋表面的钝化,提高钢筋耐Cl-侵蚀能力;阻锈剂虽未改变钢筋表面钝化膜的半导体性能,但钝化膜内载流子密度却显著下降;钝化膜致密性分析表明,随糖苷浓度增大,钢筋表面钝化膜稳定性和致密性逐渐增强,耐蚀性提高。

关 键 词:糖苷阻锈剂  钢筋  钝化膜
收稿时间:2013-07-03

Effect of Pentaerythritol Glycoside on Performance of Passive Film Formed on Steel Rebar in Saturated Ca(OH)2 Solution Containing 3.5%NaCl
ZHOU Xin,CHEN Ren,YANG Huaiyu,WANG Fuhui.Effect of Pentaerythritol Glycoside on Performance of Passive Film Formed on Steel Rebar in Saturated Ca(OH)2 Solution Containing 3.5%NaCl[J].Journal of Chinese Society For Corrosion and Protection,2014,34(2):125-130.
Authors:ZHOU Xin  CHEN Ren  YANG Huaiyu  WANG Fuhui
Affiliation:1. Department of Metallurgic Engineering, Liaoning Institute of Science and Technology, Benxi 117022, China;
2. State Key Laboratory for Corrosion and Protection, Institute of Metal Research, Chinese Academy of Sciences, Shenyang 110016, China
Abstract:The effect of PG (pentaerythritol glycoside) on the performance of the passive film on steel rebar in Ca(OH)2 saturated solution containing 3.5%NaCl, which was designed to simulate solutions in concrete pores, was investigated by mean of polarization curve measurement, Mott-Schottky analysis technique and surface analysis. The results showed that the PG could enhance the stability of the adsorption film formed on the metal surface. The curves of Csc-2 vs E of the steel rebar electrodes follow a linear Mott-Schottky (M-S) relationship with a positive slope in the range of potential from -0.5 to -0.1 V (vs SCE) in the M-S measurements, suggesting the passive film formed on the steel rebar surface was n-type semi-conductor. Moreover, with increasing concentration of inhibitor, the carrier density in passive film decreases, indicating that the passive film formed on steel rebar surface in the presence of PG was more compact and stable rather than that in the absence of inhibitor, and the corrosion resistance of passive film is gradually enhanced.
Keywords:pentaerythritol glycoside  corrosion inhibitor  steel rebar  passivation film
本文献已被 CNKI 等数据库收录!
点击此处可从《中国腐蚀与防护学报》浏览原始摘要信息