摘    要:本文介绍了一种测量500kv线路绝缘子串自然污盐密串平均值测量的新方法,总结了各种号绝缘子的积污规律,以及塔高;电压等级对绝缘子积污的影响。为500kV线路绝缘、绝缘子选型,污秽研究和线路清扫等提出了科学依据。

关 键 词:输电线路 自然积污 试验

Natural Contamination Research for 500 kV Transmission Line
Wang Jingqin, Shen Qinghe, Liu Kun, Cheng Xueqi. Natural Contamination Research for 500 kV Transmission Line[J]. Power System Technology, 1994, 18(6): 5-10,16
Authors:Wang Jingqin   Shen Qinghe   Liu Kun   Cheng Xueqi
Abstract:In this paper a new method is introduced for measuring the average value of salt density deposited on insulator string in 500kV transmission line under natural contamination.The law of natural contamination for various typesof insulator,the analysis of contamination amount,the influence of voltage class and tower height on insulator con-tamination is presented too.A trustworthy basis is provided by the method for insulation design,insulator selection. contamination research and cleaning in 500 kV transmission line.
Keywords:kV transmission line Natural contamination Sakt density  