首页 | 本学科首页   官方微博 | 高级检索  
     

桐子林水电站导流明渠大体积混凝土温度控制措施
引用本文:郭建和. 桐子林水电站导流明渠大体积混凝土温度控制措施[J]. 水力发电, 2012, 38(1): 47-49
作者姓名:郭建和
作者单位:中国人民武装警察部队水电第三总队第九支队,四川成都,611130
摘    要:桐子林水电站站址处昼夜温差大,夏季温度高。为防止导流明渠工程混凝土产生裂缝,在混凝土施工中采取了降低水化热温升、控制出机口温度、降低混凝土入仓和浇筑温度、表面养护和保护以及通水冷却等措施。施工完毕后,未发现任何裂缝。

关 键 词:大体积混凝土  温度控制  混凝土施工  桐子林水电站

Temperature Control of Mass Concrete in Diversion Channel of Tongzilin Hydropower Station
Guo Jianhe. Temperature Control of Mass Concrete in Diversion Channel of Tongzilin Hydropower Station[J]. Water Power, 2012, 38(1): 47-49
Authors:Guo Jianhe
Affiliation:Guo Jianhe(The 9th Detachment of 3rd General Contingent of Chinese People’s Armed Police Hydropower Troops, Chengdu 611130,Sichuan,China)
Abstract:Tongzilin Hydropower Station locates at the area with larger temperature difference between day and night and higher temperature in summer.To prevent crack in the concrete pouring of diversion channel,the measures are undertaken during construction,including lowering hydration heat,controlling concrete temperature at the outlet of batch plant,lowering concrete temperature during placing and pouring,concrete surface curing and protection,and water cooling.No crack is found after completion.
Keywords:mass concrete  temperature control  concrete construction  Tongzilin Hydropower Station