户外SF6断路器在严寒地区可靠运行的措施
引用本文:刘彦军,李松琴.户外SF6断路器在严寒地区可靠运行的措施[J].高压电器,2001,37(5):53-55,61.
作者姓名:刘彦军  李松琴
作者单位:平顶山天鹰集团有限责任公司
摘    要:由于SF6气体在超低温下产生部分液化,使得断路器内的SF6气体密度下降,降低了断路器的开断能力和绝缘水平;为此,提出了采用混合气体,或者采用加热SF6气体的方法,以解决高压SF6断路器在严寒地区能够可靠运行的问题。

关 键 词:六氟化硫断路器  灭弧  绝缘介质  可靠运行

RELIABLE OPERATIONAL MEASURES OF OUTDOOR SF6 CIRCUIT BREAKER AT INCLEMENT AREAS
LIU Yan jun,LI Song qin.RELIABLE OPERATIONAL MEASURES OF OUTDOOR SF6 CIRCUIT BREAKER AT INCLEMENT AREAS[J].High Voltage Apparatus,2001,37(5):53-55,61.
Authors:LIU Yan jun  LI Song qin
Abstract:SF 6 gas would liquefy partly at super low temperature, so the density of SF 6 in a circuit breaker would decrease,and so did the interrupting ability and insulation level of the circuit breaker.Two methods that is,using SF 6 mixture or heating SF 6 gas,can be taken to solve the operational reliability of HV SF 6 circuit breaker serving at the inclement area.
Keywords:SF  6circuit breaker  gas mixture  heating