首页 | 本学科首页   官方微博 | 高级检索  
     

基于光纤Bragg光栅的生物膜厚度及温度传感器
引用本文:罗彬彬,赵明富,周晓军,黄德翼,王少飞,曹雪梅.基于光纤Bragg光栅的生物膜厚度及温度传感器[J].光电子.激光,2011(6):808-812.
作者姓名:罗彬彬  赵明富  周晓军  黄德翼  王少飞  曹雪梅
作者单位:重庆理工大学电子信息工程系; 成都电子科技大学光电信息学院;;重庆理工大学电子信息工程系;;成都电子科技大学光电信息学院;;重庆理工大学电子信息工程系;;重庆理工大学电子信息工程系;;重庆理工大学电子信息工程系;
基金项目:国家自然科学基金资助项目(50876120);重庆市自然科学基金资助项目(CSTC,2010BB2298)
摘    要:提出一种基于单端腐蚀结构的光纤Bragg光栅(FBG),用于膜反应器内生物膜厚度和温度的同时测量.给出单端腐蚀FBG对外部介质折射率(SRI)与温度同时测量的理论模型,制作腐蚀区直径约为7.1~7.4μm的单端腐蚀FBG传感器.实验结果表明,传感器在SRI为1.333~1.355内具有较好的线性度,折射率灵敏度为6.8...

关 键 词:光纤传感  光纤Bragg光栅(FBG)  生物膜厚度  温度  折射率  单端腐蚀

Biofilm thickness and temperature sensor based on fiber Bragg grating
LUO Bin-bin,ZHAO Ming-fu,ZHOU Xiao-jun,HUANG De-yi,WANG Shao-fei and CAO Xue-mei.Biofilm thickness and temperature sensor based on fiber Bragg grating[J].Journal of Optoelectronics·laser,2011(6):808-812.
Authors:LUO Bin-bin  ZHAO Ming-fu  ZHOU Xiao-jun  HUANG De-yi  WANG Shao-fei and CAO Xue-mei
Affiliation:Department of Electronic Engineering,Chongqing University of Technology,Chongqing 400054,China; School of Optoelectronic Information,University of Electronic Science and Technology of China,Chengdu 610054,China;Department of Electronic Engineering,Chongqing University of Technology,Chongqing 400054,China;;School of Optoelectronic Information,University of Electronic Science and Technology of China,Chengdu 610054,China;Department of Electronic Engineering,Chongqing University of Technology,Chongqing 400054,China;;Department of Electronic Engineering,Chongqing University of Technology,Chongqing 400054,China;;Department of Electronic Engineering,Chongqing University of Technology,Chongqing 400054,China;
Abstract:A biofilm sensor based on the single-end etched fiber Bragg grating(FBG) is proposed and is used for simultaneous measurement of biofilm thickness and temperature in the biofilm reactor.The theoretical model for the simultaneous measurement of surrounding refractive index(SRI) and temperature by the single-end etched FBG is presented,and the linear approximation for the SRI sensitivity is given.A single-end etched FBG with the diameter of the etched region of approximately 7.1-7.4 μm was fabricated.Experimental results demonstrate that the sensor shows a good linear property and SRI sensitivity of 6.894±0.029 nm/riu in the refractive index range from 1.333 to about 1.355,approximately agreeing with the simulated value of 6.83 nm/riu.Also,by using a spectral unit with wavelength resolution of 1 pm,the resolutions of 15.36±0.85 μm and 0.12 ℃ for the biofilm thickness and temperature are realized respectively.
Keywords:optical fiber sensing  fiber Bragg grating(FBG)  bioflim thickness  temperature  refractive index  single-end etched
本文献已被 CNKI 等数据库收录!
点击此处可从《光电子.激光》浏览原始摘要信息
点击此处可从《光电子.激光》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号