首页 | 本学科首页   官方微博 | 高级检索  
     

Analysis of the Water Hammer in the Secondary Loop of CEFR
作者姓名:TANG  Long  WANG  Bin
摘    要:

关 键 词:中国实验快堆  二回路系统  水锤  事故分析  钠水分析

Analysis of the Water Hammer in the Secondary Loop of CEFR
TANG Long WANG Bin.Analysis of the Water Hammer in the Secondary Loop of CEFR[J].Annual Report For China Institute of Atomic Energy,2005(1):8-8.
Abstract:The coolant of the primary loop and secondary loop of CEFR is sodium. The reaction of sodium with water during the leakage of SG will induce the water hammer in the secondary loop. The water hammer in the loop would cause the pipeline to swing, the support of the pipeline to snap, the pipeline to break, even the nuclear power station to shutdown directly. The water hammer is an important issue of the design and safe analysis of CEFR.
Keywords:
本文献已被 维普 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏