2. 湖南华电长沙发电有限公司,湖南长沙,410203
摘    要:结焦是流化床锅炉在启动、运行过程中经常碰到的事故。针对某厂75 t/h循环流化床锅炉调试期间发生的2次结焦事故原因进行分析,制定预防控制措施,有效地解决了该锅炉结焦问题。

关 键 词:循环流化床锅炉  结焦  流化

Cause analysis of slagging on CFB boiler and precaution
LEI Lin,LI Shi-ping,CHEN Yi-ping.Cause analysis of slagging on CFB boiler and precaution[J].Hunan Electric Power,2010,30(4):35-37.
Authors:LEI Lin  LI Shi-ping  CHEN Yi-ping
Affiliation:1. Hunan Electric Power Test & Research Institute, Changsha 410007, China; 2. Hunan Huadian Changsha Power Generation Co., Ltd, Changsha410203, China)
Abstract:Slagging is often happened on start-up and operation process of CFB boiler. This paper analyzes the causes of two slagging accidents happened on 75 t/h CFB boiler start-up commissioning and gives the countermeasures which can effectively solve the problem.