重庆某电信大楼消防给水稳压方式的选择 |
| |
引用本文: | 童愚.重庆某电信大楼消防给水稳压方式的选择[J].重庆建筑,2011,10(12):53-55. |
| |
作者姓名: | 童愚 |
| |
作者单位: | 机械工业第三设计研究院 重庆400039 |
| |
摘 要: | 详细介绍了三种消防给水稳压方式,通过对小稳压泵配大气压罐和大稳压泵(增压泵)配小气压罐的这两种稳压增压方式的比较计算分析,并针对某具体工程来讨论确定最佳消防给水稳压方案。
|
关 键 词: | 稳压方式 气压罐 稳压泵 稳压水容积 |
Choice of Stable Fire Protection Water Pressure in a Certain Building |
| |
Authors: | Tong-Yu |
| |
Abstract: | Three detailed fire control water stable pressure ways are introduced in the article, and the best water-giving programs are discussed after lengthy comparisons are made between the complicated calculations resulting from the small stable pressure pumps and huge stable pressure pumps. |
| |
Keywords: | stable pressure ways air pressure tank stable pressure pump stable pressure water volume |