首页 | 本学科首页   官方微博 | 高级检索  
     

内螺旋管金属氢化物反应器吸氢过程数值分析及优化
引用本文:鲍泽威,刘亮,袁晟毅.内螺旋管金属氢化物反应器吸氢过程数值分析及优化[J].四川大学学报(工程科学版),2015,47(5):185-190.
作者姓名:鲍泽威  刘亮  袁晟毅
作者单位:四川大学,四川大学,四川大学
基金项目:中央高校基本科研业务费资助“基于“火积”耗散理论的金属氢化物蓄热反应器优化研究”(2014SCU11022)
摘    要:针对金属氢化物反应器传热性能较差的问题,采用田口方法对内置螺旋换热管的氢化物反应器进行了优化研究。建立了金属氢化物反应器的三维多物理场耦合模型并采用COMSOL Multiphysics V4.4软件来求解。采用田口方法安排出具有代表性的螺旋结构参数组合,通过反应器模型计算得到各个组合的性能。结果表明:螺旋管的换热系数和换热面积都较大,因此内置螺旋管的氢化物反应器的性能较理想;随着螺旋数N和螺旋管直径do的增加,反应器的单位重量蓄热功率GHSR大大提高,而螺旋线直径D对反应器性能影响很小;最优的螺旋管参数组合为:D=32mm、N=6和do=8mm,相应的GHSR达到62.90W/kg。

关 键 词:金属氢化物  反应器  螺旋换热管  田口方法  蓄热
收稿时间:2014/12/29 0:00:00
修稿时间:2015/3/15 0:00:00

Numerical Analysis and optimization of metal hydride reactors incorporating helical coils during adsorption
Bao Zewei,and.Numerical Analysis and optimization of metal hydride reactors incorporating helical coils during adsorption[J].Journal of Sichuan University (Engineering Science Edition),2015,47(5):185-190.
Authors:Bao Zewei  and
Affiliation:Sichuan University,,
Abstract:The heat transfer performance of metal hydride reactors is poor. To solve this problem, Taguchi methods was used to optimize the design parameters of metal hydride reactors equipped with helical coil heat exchanger. A three-dimensional multi-physics model for the metal hydride reactor was proposed and solved using the commercial software package COMSOL Multiphysics V4.4. Some typical combinations of structural parameters for helical coil tubes were selected by using Taguchi methods, and the performance of the reactors with different helical coil tubes was evaluated by numerical simulations based on the reactor model. The analysis results indicated that the performance of the metal hydride reactor equipped with the helical coil heat exchanger was better because the heat transfer coefficient and the heat transfer area of the helical coil heat exchanger were larger in compared with the straight tube. As the pitch number of the helical coil (N) and the minor radius of the helical coil (do) increased, the gravimetric heat storage rate (GHSR) increased. However, the major radius of the helical coil (D) had a little effect on the reactor performance. The optimal parameters of the reactor were given as following: D was 32 mm, N was 6 and do was 8 mm, and accordingly the maximum value of GHSR was 62.90 W/kg.
Keywords:metal hydride  reactor  helical coil heat exchanger  Taguchi methods  heat storage
本文献已被 万方数据 等数据库收录!
点击此处可从《四川大学学报(工程科学版)》浏览原始摘要信息
点击此处可从《四川大学学报(工程科学版)》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏