Life cycle cost analysis of HPVT air collector under different Indian climatic conditions
Authors:Vivek Raman  GN Tiwari
Affiliation:Centre for Energy Studies, IIT Delhi, Hauz Khas, New Delhi, India
Abstract:In this communication, a study is carried out to evaluate an annual thermal and exergy efficiency of a hybrid photovoltaic thermal (HPVT) air collector for different Indian climate conditions, of Srinagar, Mumbai, Jodhpur, New Delhi and Banglore. The study has been based on electrical, thermal and exergy output of the HPVT air collector. Further, the life cycle analysis in terms of cost/kWh has been carried out. The main focus of the study is to see the effect of interest rate, life of the HPVT air collector, subsidy, etc. on the cost/kWh HPVT air collector. A comparison is made keeping in view the energy matrices. The study reveals that (i) annual thermal and electrical efficiency decreases with increase in solar radiation and (ii) the cost/kWh is higher in case of exergy when compared with cost/kWh on the basis of thermal energy for all climate conditions. The cost/kWh for climate conditions of Jodhpur is most economical.
Keywords:Hybrid photovoltaic thermal (HPVT) air collector  Life cycle cost analysis  Solar energy