基于故障-测点互信息的传感器多目标优化配置
引用本文:于保华,杨世锡,周晓峰. 基于故障-测点互信息的传感器多目标优化配置[J]. 浙江大学学报(工学版), 2012, 46(1): 156-162. DOI: 10.3785/j.issn.1008-973X.2012.01.25
作者姓名:于保华  杨世锡  周晓峰
作者单位:1. 浙江大学 机械工程学系,浙江 杭州 310027 ;2. 杭州电子科技大学 机械工程学院,浙江 杭州 310018
基金项目:国家“863”高技术研究发展计划资助项目(2008AA04Z410);国家自然科学基金资助项目(50675194);浙江省自然科学基金资助项目(Y1080843)
摘    要:针对大型流程工业系统状态监测故障诊断的传感器优化配置特点,建立能够定量反映测点获取故障信息效率的故障-测点互信息矩阵.提出传感器系统测点-故障关联度优化目标函数,建立兼顾测点获取故障信息效率、传感器系统可靠性、经济性的多目标优化配置模型.设计改进的非支配排序遗传算法(NSGA-II),在保证故障可检测性和可分辨性的前提下,获得兼顾3大优化目标的Pareto前沿解集.电站除氧器的实例分析表明了该方法的可行性和有效性.

关 键 词:故障-测点互信息  测点-故障关联度  传感器优化配置  非支配排序遗传算法(NSGA)

Optimization of sensor allocation based on fault-measurement point mutual information
YU Bao-hua,YANG Shi-xi,ZHOU Xiao-feng. Optimization of sensor allocation based on fault-measurement point mutual information[J]. Journal of Zhejiang University(Engineering Science), 2012, 46(1): 156-162. DOI: 10.3785/j.issn.1008-973X.2012.01.25
Authors:YU Bao-hua  YANG Shi-xi  ZHOU Xiao-feng
Affiliation:1(1.Department of Mechanical Engineering,Zhejiang University,Hangzhou 310027,China; 2.School of Mechanical Engineering,Hangzhou Dianzi University,Hangzhou 310018,China)
Abstract:A matrix of fault-measurement point mutual information was proposed which can quantitatively reflect the efficiency of the fault diagnose information obtained by the measurement point in order to find the optimized allocation of sensors for large process industries to meet the fault diagnose requirement.An optimized target function based on the correlation of measurement point to fault on the sensor system was created.A multi-objective optimized allocation model was conducted which can consider the following three things: the efficiency of the fault diagnosis information obtained by the measurement point,the reliability of sensor systems and the cost factor.A promoted non-dominated sorted genetic algorithm-II(NSGA-II) was designed,which can gain Pareto front solutions including three above-mentioned optimized-targets under the premise of assuring the detectability and separability of fault.The case of power plant deaerator shows that the method is feasible and effective.
Keywords:fault-measurement point mutual information  correlation of measurement point to fault  optimization of sensor allocation  non-dominated sorted genetic algorithm(NSGA)
本文献已被 CNKI 等数据库收录!
点击此处可从《浙江大学学报(工学版)》浏览原始摘要信息