Connecting hose’s operating characteristics and its effect on the cooling performance of an 80 K Oxford split-Stirling-cycle cryocooler
Authors:C.Q. Zhang  Y.N. Wu  D.Y. Liu
Affiliation:a Refrigeration and Cryogenics Engineering Institute, Shanghai Jiaotong University, Shanghai 200030, China
b Shanghai Institute of Technical Physics, Chinese Academy of Sciences, Shanghai 200083, China
Abstract:In this paper, a mathematical model on the connecting hose of a one-stage Oxford split-Stirling cryocooler has been made to simulate its dynamic performance. A set of governing equations has been discretized by method of characteristics and dissolved by a numerical method. The present paper emphasizes the validation of this model against experimental results of pressure phase lag and amplitude attenuation through connecting hose, and cooler performance vs. connecting hose in different dimensions. The comparison shows acceptable agreement between the simulation and experimental results.
Keywords:Oxford split-Stirling cryocooler   Connecting hose   Characteristics   Cooler performance
本文献已被 ScienceDirect 等数据库收录!