首页 | 本学科首页   官方微博 | 高级检索  
     


Experimental investigation on film cooling performance of pressure side in annular cascades
Authors:Guoqing Li  Hongwu Deng
Affiliation:(1) Faculty of Mechanical Engineering, K.N. Toosi University of Technology, No.15, Pardis St., Mola Sadra St., Vanak Sq., Tehran, Iran
Abstract:Experimental investigations were conducted to study the film cooling performance in a low speed annular cascades using Thermochromic Liquid Crystal (TLC) technique. The test blade was placed in the second stage, where 18 blades were installed with chord length of 124.3 mm and height of 99 mm. A film hole with diameter of 4 mm, angled 28° to the tangential of the pressure surface in streamwise, was set in the middle span of the blade. The Reynolds number based on the outlet mainstream velocity and the blade chord length of the second stage varied from 1.52×105 to 2.00×105. All measurements were made with the blowing ratio varying from 0.3 to 3.0. Air and CO2 worked as coolant to achieve the coolant-to-mainstream density ratio of 1.03 and 1.57. The results show that the film coverage and cooling effectiveness scale up with the blowing ratio. Higher density ratio can generate larger film cooling coverage and effectiveness. The higher the Reynolds number, the larger the film coverage and cooling effectiveness.
Keywords:film cooling  annular cascades  blowing ratio  density ratio  effectiveness  
本文献已被 CNKI 维普 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号