首页 | 本学科首页   官方微博 | 高级检索  
     

连续方波脉冲电压下温度对聚酰亚胺薄膜局部放电特性的影响
引用本文:罗杨,吴广宁,王鹏,张依强,曹开江,徐慧慧,辛正亮.连续方波脉冲电压下温度对聚酰亚胺薄膜局部放电特性的影响[J].中国电机工程学报,2012(19):154-160,199.
作者姓名:罗杨  吴广宁  王鹏  张依强  曹开江  徐慧慧  辛正亮
作者单位:西南交通大学电气工程学院,四川省成都市610031
基金项目:国家自然科学基金项目(51177136)~~
摘    要:为了评估温度对局部放电(partial discharge,PD)特性的影响,对连续方波脉冲电压条件下的局部放电测试系统进行了改进,并采用该系统测试变频电机用聚酰亚胺纳米复合薄膜在不同温度条件下的局部放电特性,分析了不同温度下的局部放电散点图、放电次数及绝缘寿命。试验结果表明:局部放电多集中在方波脉冲的上升沿及下降沿附近,且在电压负半周期平顶区内,出现了大量放电;同时,随着实验温度的增加,局部放电次数及放电幅值虽然降低,但聚酰亚胺的绝缘寿命也逐渐降低,这说明局部放电只是引起聚酰亚胺纳米复合薄膜绝缘失效的原因之一,高温条件下活性电子的入陷、脱陷过程及空间电荷造成的电场畸变可能是诱导绝缘失效的另一个因素。

关 键 词:局部放电  变频电机  聚酰亚胺纳米复合薄膜  连续方波脉冲电压  空间电荷  绝缘失效

Effect of Temperature on Partial Discharge Properties of Polyimide Film Under Continuous Square Impulse Voltage
LUO Yang,WU Guangning,WANG Peng,ZHANG Yiqiang,CAO Kaijiang,XU Huihui,XIN Zhengliang.Effect of Temperature on Partial Discharge Properties of Polyimide Film Under Continuous Square Impulse Voltage[J].Proceedings of the CSEE,2012(19):154-160,199.
Authors:LUO Yang  WU Guangning  WANG Peng  ZHANG Yiqiang  CAO Kaijiang  XU Huihui  XIN Zhengliang
Affiliation:(School of Electrical Engineering,Southwest Jiaotong University,Chengdu 610031,Sichuan Province,China)
Abstract:In order to evaluate the influences of temperature on partial discharge(PD) properties,a PD testing system with variable test temperature was improved.The PD characteristics of polyimide nanocomposite films used in inverter-fed motors were investigated.The amount,amplitudes,and scatter diagrams of PD pulses which were obtained under different testing temperatures were presented.The results show than most of the PD pulses appear near the rising and falling edge of the continuous square impulse voltage.Some PD pulses are observed during the flat zone of negative semi-period of continuous square impulse voltage.However,PD pulses could hardly appear during the flat zone of positive semi-period.Although the amount and amplitudes of PD pluses decrease gradually with the increase of testing temperature,the life time of polyimide nanocomposite films also reduces.It is demonstrated that PD is only one of the factors which causes the damage of polyimide nanocomposite films.Under high temperature,the trapped and de-trapped processes of active electron and the distorted local field caused by space charge are the other reasons which induce the insulation damage.
Keywords:partial discharge(PD)  inverter-fed traction motor  polyimide nanocomposite film  continuous square impulse voltage  space charge  insulation failure
本文献已被 CNKI 万方数据 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号