摘    要:介绍了中国计量科学研究院研制的中温区真空标准黑体辐射源的结构设计,工作原理,测试结果和不确定度评定.黑体辐射源工作温度范围为320~500 K,黑体空腔开口直径为50 mm,空腔深度为260 mm,表面喷涂了耐高温漆,空腔发射率优于0.999.真空环境下测试了黑体在335~500K温度范围内的轴向温度均匀性,温度稳定性...

关 键 词:计量学  红外遥感  黑体辐射源  中温区  发射率  辐射亮度温度  不确定度
收稿时间:2020-11-05

Development of Vacuum Standard Blackbody Radiation Source in Middle Temperature Zone
YANG Yan-long,HAO Xiao-peng,SONG Jian,LIU Yang,HU You-hua,XIE Chen-yu,LIU Yan,XIE Lin-lin.Development of Vacuum Standard Blackbody Radiation Source in Middle Temperature Zone[J].Acta Metrologica Sinica,2021,42(2):129-136.
Authors:YANG Yan-long  HAO Xiao-peng  SONG Jian  LIU Yang  HU You-hua  XIE Chen-yu  LIU Yan  XIE Lin-lin
Affiliation:1. College of Applied Nuclear Technology and Automation Engineering, Chengdu University of Technology, Chengdu, Sichuan 610059, China
2. National Institute of Metrology, Beijing 100029, China
Abstract:The structure design,working principle,test results and uncertainty evaluation of the medium temperature vacuum standard blackbody radiation source developed by National Institution of Metrology in China are introduced.The black body radiation source has a working temperature range of 320~500 K,the black body cavity aperture diameter is 50 mm,the cavity depth is 260 mm,the surface is sprayed with high temperature paint,and the cavity emissivity is better than 0.999.The blackbody's axial temperature uniformity,temperature stability and blackbody radiation source brightness temperature were tested in vacuum,and the blackbody temperature uniformity is better than 0.15 K,and the temperature stability within 40 min is better than 0.03 K.The uncertainty sources of black body radiation source are analyzed,and the combined standard uncertainty of the black body radiation source is better than 0.04 K.
Keywords:metrology  infrared remote sensing  black body radiation source  middle temperature zone  emissivity  radiant brightness temperature  uncertainty analysis
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《计量学报》浏览原始摘要信息
点击此处可从《计量学报》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号