Influence of a flow obstacle on the occurrence of burnout in boiling two-phase upward flow within a vertical annular channel
Authors:S. Mori  T. Fukano  
Affiliation:Department of Mechanical Engineering Science, Faculty of Engineering, Kyushu University 6-10-1, Hakozaki, Higashi-ku, Fukuoka 812-8581, Japan
Abstract:When a flow obstruction such as a cylindrical spacer is set in a boiling two-phase flow within an annular channel, the inner tube of which is used as a heater, the temperature on the surface of the heating tube is severely affected by its existence. In some cases, the cylindrical spacer has a cooling effect, and in the other cases it causes the dryout of the cooling water film on the heating surface resulting in the burnout of the heating tube.In the present paper, we have focused our attention on the influence of a flow obstacle on the occurrence of burnout of the heating tube in boiling two-phase flow.The results are summarized as follows:
(1)When the heat flux approaches the burnout condition, the wall temperature on the heating tube fluctuates with a large amplitude. And once the wall temperature exceeds the Leidenfrost temperature, the burnout occurs without exception.
(2)The trigger of dryout of the water film which causes the burnout is not the nucleate boiling but the evaporation of the base film between disturbance waves.
(3)The burnout never occurs at the downstream side of the spacer. This is because the dryout area downstream of the spacer is rewetted easily by the disturbance waves.
Keywords: