摘    要:针对某炼油厂加氢车间蜡油泵切换到备用泵时存在严重供量不足问题 ,通过应用故障树分析法 ,从操作者、介质、管路及泵本身等方面入手 ,建立了故障原因分析树 ,指出了可能造成供量不足的原因

关 键 词:蜡油泵  供量不足  故障树  原因分析

Analysis of the Unsufficient Delivery of Wax-Oil Pump of Hydrogenation Plant
Sun Tie Wang Zheng Liu Lu. Analysis of the Unsufficient Delivery of Wax-Oil Pump of Hydrogenation Plant[J]. Journal of Petrochemical Universities, 1997, 10(1): 65-68
Authors:Sun Tie Wang Zheng Liu Lu
Abstract:The delivery capacity of the wax-oil pump is not sufficient as the pump on duty is switched off to reserved pump,having an influnce on continuous operation in hydrogenation unit.Based on the operator,medium,pipeline and the pump itself,using the analysis of Fault Tree,the analytical tree of cause of the unsufficient delivery was set up.The factors of unsufficient delivery were presented.