某大型车间冷却水系统控制策略
引用本文:张成礼,庞洛明. 某大型车间冷却水系统控制策略[J]. 制冷与空调(北京), 2012, 0(3): 90-92,135
作者姓名:张成礼  庞洛明
作者单位:中国汽车工业工程公司
摘    要:某车间冷却水系统采用空调机组、冷却塔换热器和冷冻水换热器这3种冷却方式,介绍其控制原则,并分别讨论这3种冷却方式的控制策略,通过尽量使用高性能指数冷却源、合理分担负荷、设备间协调运行实现精确控制、节能高效的目的。

关 键 词:冷却水  冷却塔  换热器  PI控制  负荷

Control strategy of cooling water system of one large-scale workshop
Zhang Chengli Pang Luoming. Control strategy of cooling water system of one large-scale workshop[J]. Refrigeration and Air-conditioning, 2012, 0(3): 90-92,135
Authors:Zhang Chengli Pang Luoming
Affiliation:Zhang Chengli Pang Luoming(China Automobile Industry Engineering Corporation)
Abstract:The cooling water system of a large workshop includes 3 cooling methods:air handling unit,cooling tower and chilled water.The control principle of the system is introduced.The control strategies about its cooling methods are discussed.More using the cooling source with higher cooling coefficient performance,sharing the load reasonable,coordinated operation between devices would achieve safe operation,precise control and energy conservation.
Keywords:cooling water  cooling tower  heat exchanger  PI controller  load