Performance assessment of HC-290 as a drop-in substitute to HCFC-22 in a window air conditioner
Authors:S Devotta  AS Padalkar  NK Sane
Affiliation:aNational Environmental Engineering Research Institute, Nehru Marg, Nagpur 44020, India;bProcess Development Division, National Chemical Laboratory, Homi Bhabha Road, Pune 411008, India;cDepartment of Mechanical Engineering, Walchand College of Engineering, Sangli 416415, India
Abstract:As per the Montreal Protocol, CFCs and HCFCs are being phased out. HCFC-22 is used in window air conditioners. This paper presents the experimental performance study of a window air conditioner with propane (HC-290), a natural refrigerant, as a drop-in substitute to HCFC-22. Experimental results showed that HC-290 had 6.6% lower cooling capacity for the lower operating conditions and 9.7% lower for the higher operating conditions with respect to HCFC-22. The coefficient of performance for HC-290 was 7.9% higher for the lower operating conditions and 2.8% higher for the higher operating conditions. The energy consumption of the unit with HC-290 was lower in the range 12.4–13.5% than HCFC-22. The discharge pressures for HC-290 were lower in the range 13.7–18.2% than HCFC-22. For HC-290, the pressure drop was lower than HCFC-22 in both heat exchangers.This paper also presents simulation results for the heat exchangers of an HCFC-22 window air conditioner with HC-290 as a drop-in substitute. The simulation has been carried out using EVAP-COND, a heat exchanger model developed by NIST National Institute of Standards and Technology. EVAP-COND: simulation models for finned-tube heat exchangers, Maryland, USA (2003). http://www2.bfrl.nist.gov/software/evap-cond/ 18]]. The simulated evaporator capacities are within ±4% of the experimentally measured cooling capacities for both refrigerants. Simulation results for HC-290 and HCFC-22 are compared. The exit temperatures of HC-290 are lower by 0.3–1.2 °C in the condenser and are higher by 2.1–2.4 °C in the evaporator than HCFC-22. Evaporating pressures of HC-290 are lower by 2.1–3.3% as compared to HCFC-22. The pressure drops of HC-290 are lower in both the evaporator and the condenser as compared to HCFC-22. The outlet temperatures of air for HCFC-22 and HC-290 in both heat exchangers are nearly the same.
Keywords:Air conditioner  Window  Experiment  Propane  R-22  Performance  COP  Simulation  EvaporatorMots clé  s: Conditionneur d'air  Fenê  tre  Expé  rimentation  Propane  R-22  Performance  COP  Simulation  É  vaporateur
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号