火电厂直接空冷系统凝结水溶氧超标的治理
引用本文:张国庆. 火电厂直接空冷系统凝结水溶氧超标的治理[J]. 电力学报, 2007, 22(2): 201-203
作者姓名:张国庆
作者单位:山西大学工程学院,山西,太原,030013
摘    要:文章分析了火电厂直接空冷机组凝结水溶氧超标的原因及其对机组运行造成的危害,提出了治理空冷机组凝结水溶氧超标的方案,在几个电厂中应用的效果令人满意。

关 键 词:直接空冷  凝结水  溶解氧  补水  除氧
文章编号:1005-6548(2007)02-0201-03
修稿时间:2007-02-12

The Solution of Exceeding Dissdved Oxygen in Condensation Water of Power Plant Direct Air-cooling System
ZHANG Guo-qing. The Solution of Exceeding Dissdved Oxygen in Condensation Water of Power Plant Direct Air-cooling System[J]. Journal of Electric Power, 2007, 22(2): 201-203
Authors:ZHANG Guo-qing
Affiliation:Engineering College of Shanxi University, Taiyuan 030013, China
Abstract:This article analyzed the causes for exceeding dissolved oxygen in condensation water of the direct air-cooling power units and the harm caused,and put forward the corresponding solution.The results of the application were satisfactory.