Historical perspective on failure rates for US commercial reactor components |
| |
Authors: | S. A. Eide |
| |
Affiliation: | Idaho National Engineering and Environmental Laboratory, P.O. Box 1625, Idaho Falls, ID 83415-3850, USA |
| |
Abstract: | To support the development of probabilistic risk assessments of US commercial nuclear power plants, significant effort has been expended to develop generic failure rates for components. Generic failure rates indicate industry-average performance of components, rather than component performance at a specific plant. Most publicly available, generic failure rate databases are typically based on data collected in the 1970s and 1980s for US nuclear power plants. Recent data analysis programs sponsored by the US Nuclear Regulatory Commission and data collection programs sponsored by the Institute of Nuclear Power Operations provide an opportunity to compare more recent failure rate estimates with those obtained in the 1970s and 1980s. These recent results indicate that many component generic failure rates are now lower than observed in the 1970s and 1980s. Suggestions for up-to-date failure rates are presented. Also, failure to run rates for standby components are presented for both short- and longer-term run times. |
| |
Keywords: | Component reliability Component failure rate Failure database |
本文献已被 ScienceDirect 等数据库收录! |
|