Thermal characteristics in a heat exchanger tube fitted with dual twisted tape elements in tandem
Authors:Smith Eiamsa-ard  Chinaruk Thianpong  Petpices Eiamsa-ard  Pongjet Promvonge
Affiliation:1. Department of Mechanical Engineering, Faculty of Engineering, Mahanakorn University of Technology, Bangkok 10530, Thailand;2. Department of Mechanical Engineering, Faculty of Engineering, King Mongkut''s Institute of Technology Ladkrabang, Bangkok 10520, Thailand
Abstract:The paper presents a comparative investigation of enhanced heat transfer and pressure loss by insertion of single twisted tape, full-length dual and regularly-spaced dual twisted tapes as swirl generators, in a round tube under axially uniform wall heat flux (UHF) conditions. The investigation encompassed the Reynolds number based on the inlet tube diameter (D) ranging from 4000 to 19,000. The experiments are performed using single twisted tapes and full-length dual twisted tapes with three different twist ratios (y/w = 3.0, 4.0 and 5.0) and also regularly-spaced dual twisted tapes with three different space ratios (s/D = 0.75, 1.5 and 2.25). The effects of major parameters on heat transfer and friction factor are discussed and the results from both single and dual twisted tape inserts are compared with those from the plain tube. The result shows that the heat transfer of the tube with dual twisted tapes is higher than that of the plain tube with/without single twisted tape insert. For both single twisted tape and full-length dual twisted tapes, Nusselt number (Nu) and friction factor (f) tend to increase with decreasing twist ratio (y/w). The average Nusselt number and friction factor in the tube fitted with the full-length dual twisted tapes at y/w = 3.0, 4.0 and 5.0, are respectively 146%, 135% and 128%; and 2.56, 2.17 and 1.95 times of those in the plain tube. For the regularly-spaced dual twisted tapes, the heat transfer rate is decreased with increasing space ratio (s/D). The average Nusselt numbers in the tube fitted with the regularly-spaced dual twisted tapes (s/D) of 0.75, 1.5 and 2.25 are respectively, 140%, 137% and 133% of that in the plain tube. With the similar trend mentioned above, all dual twisted tapes with free spacing yield lower heat transfer enhancement in comparison with the full-length dual twisted tapes (s/D = 0.0).
Keywords:Heat transfer   Friction factor   Single twisted tape   Dual twisted tapes   Swirl flow
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号