首页 | 本学科首页   官方微博 | 高级检索  
     


Energetic and exergetic performance evaluation of a combined heat and power system with the micro gas turbine (MGTCHP)
Authors:Ozgur Balli  Haydar Aras
Affiliation:1. First Air Supply and Maintenances Center, TUAF, Eskisehir, Turkey;2. Department of Mechanical Engineering, Engineering and Architecture Faculty, Eskisehir Osmangazi University, Eskisehir, Turkey
Abstract:This study deals with the energetic and exergetic performance assessment of a combined heat and power system with micro gas turbine (MGTCHP). Quantitative energy and exergy balance for each component and the whole MGTCHP system was considered, while energy and exergy consumption within the system were determined. The performance characteristics of this MGTCHP system were evaluated using energy and exergy analyses methods. The energetic and exergetic efficiencies of the MGTCHP system are calculated as 75.99% with 254.55 kW (as 99.15 kW—electrical and 155.40 kW—hot water@363.15 K) and 35.80% with 123.61 kW (as 99.15 kW—electrical and 24.46 kW—hot water@363.15 K), respectively. The maximum energy loss and exergy consumption occur at 44.03 kW in the stack gas and 129.61 kW in the combustion chamber, respectively. Copyright © 2007 John Wiley & Sons, Ltd.
Keywords:combined heat and power  cogeneration  micro gas turbine  energy  exergy  energy analysis  exergy analysis  energy efficiency  exergy efficiency
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号