摘    要:通过居龙滩水电厂灯泡贯流式机组运行时某些部位(如水导轴承)振动幅值超标的现象,从导叶和桨叶协联关系、机组的结构特点、运行工况等方面分析了振动幅值超标的原因,并提出如何利用机组的振动测量值指导机组的运行,从而保证机组的安全运行。

关 键 词:灯泡贯流式机组  振动  测量值  运行指导

Significance of vibration measurement for bulb tubular hydraulic generating unit operation
Wang Li-gang. Significance of vibration measurement for bulb tubular hydraulic generating unit operation[J]. Jiangxi Electric Power, 2009, 33(1): 14-15
Authors:Wang Li-gang
Abstract:Due to excessive vibration amplitude occurred in some parts of bulb tubular hydraulic generating unit such as turbine guide bearing,the reason for excessive amplitude was analyzed according to the relation between guide vane and blade,the structure of unit and the operation.The significance of vibration measurement for bulb tubular hydraulic generating unit operation was pointed out.