变电站20kV接线方式的最优选择
引用本文:梁振升. 变电站20kV接线方式的最优选择[J]. 电力建设, 2012, 33(1): 54-56. DOI: 10.3969/j.issn.1000-7229.2012.01.012
作者姓名:梁振升
作者单位:广州电力设计院,广州市,510610
摘    要:针对110/20 kV、220/20 kV变电站20 kV侧的几种可选接线方式,从可靠性、灵活性、经济性、过负荷裕度和工程投资等多项技术经济指标进行分析比较,提出20 kV侧的最优接线方案,为合理选择工程接线提供依据.

关 键 词:变电站  接线方式  可靠性
收稿时间:2011-11-04
修稿时间:2011-11-20

Optimal Selection of 20 kV Connection Mode for Substation
LIANG Zhensheng. Optimal Selection of 20 kV Connection Mode for Substation[J]. Electric Power Construction, 2012, 33(1): 54-56. DOI: 10.3969/j.issn.1000-7229.2012.01.012
Authors:LIANG Zhensheng
Affiliation:LIANG Zhensheng(Guangzhou Electric Power Design Institute,Guangzhou 510610,China)
Abstract:Aiming at several optional connection modes of 20 kV for 110/20 kV and 220/20 kV substation, the technical and economic indexes are analyzed of reliability, flexibility, economy, adequacy and investment, as a result that the optimal selection is proposed for design, providing references for feasible selection of engineering connection.
Keywords:substation  connection mode  reliability