首页 | 本学科首页   官方微博 | 高级检索  
     

MTF Measurement of EBCCD Imaging System by Using Super Resolution Technique
引用本文:左昉,高岳,高稚允,苏美开,周立伟. MTF Measurement of EBCCD Imaging System by Using Super Resolution Technique[J]. 北京理工大学学报(英文版), 2003, 12(2): 125-128
作者姓名:左昉  高岳  高稚允  苏美开  周立伟
作者单位:DeptartmentofOpticalEngineering,SchoolofInformationScienceandTechnology,BeijingInstituteofTechnology,Beijing100081,China
基金项目:SponsoredbytheMinisterialLevelAdvancedResearchFoundation
摘    要:Existing methods of measurement MTF for discrete imaging system are analysed. A slit target is fre-quently used to measure the MTF for an imaging system. Usually there are four methods to measure the MTF for a discrete imaging system by using a slit. These methods have something imperfect respectively. But for the dis-crete imaging systems of under sampling it is difficult to reproduce this type of target properly since frequencies above Nyquist are folded into those below Nyquist, resulting in aliasing effect. To tackle the aliasing problem, a super resolution technique is introduced into our measurement, which gives MTF values both above and below Nyquist more accurately.

关 键 词:EBCCD 调制传递函数 超分辨率 光电器件 微光技术 成像系统 测量技术
收稿时间:2002-08-29

MTF Measurement of EBCCD Imaging System by Using Super Resolution Technique
ZUO Fang,GAO Yue,GAO Zhi yun,SU Mei kai and ZHOU Li wei. MTF Measurement of EBCCD Imaging System by Using Super Resolution Technique[J]. Journal of Beijing Institute of Technology, 2003, 12(2): 125-128
Authors:ZUO Fang  GAO Yue  GAO Zhi yun  SU Mei kai  ZHOU Li wei
Affiliation:Deptartment of Optical Engineering, School of Information Science and Technology, Beijing Institute of Technology, Beijing 100081, China
Abstract:Existing methods of measurement MTF for discrete imaging system are analysed. A slit target is frequently used to measure the MTF for an imaging system. Usually there are four methods to measure the MTF for a discrete imaging system by using a slit. These methods have something imperfect respectively. But for the discrete imaging systems of under sampling it is difficult to reproduce this type of target properly since frequencies above Nyquist are folded into those below Nyquist, resulting in aliasing effect. To tackle the aliasing problem, a super resolution technique is introduced into our measurement, which gives MTF values both above and below Nyquist more accurately.
Keywords:EBCCD  modulation transfer function  super resolution  low light level imaging
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《北京理工大学学报(英文版)》浏览原始摘要信息
点击此处可从《北京理工大学学报(英文版)》下载全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号